Advantages
1. Free custom programming to your exact requirements included with every charger. Also free email technical support and half-price reprogramming for the life of the charger.
2. Internal integrated PFC, no pollution to electric network, minimizes disturbance on electric network from heavy current.
3. Wide input voltage range AC85V~AC265V available for worldwide requirements, convenient for electric-network fluctuation and vehicles exportation.
4. High efficiency, above 93%, while traditional chargers can meet only about 80% efficiency.
5. Intelligent temperature compensation function in the charging process, preventing damage to the battery caused by charge-off or charge due, greatly extending the lifespan of the battery.
6. Fully-sealed and water-proof, protection class IP46. Shock resistance treatment made inside makes vibration-proof level up to SAEJ1378 that can fully meet the standard of automobile appliance usage.
7. Available for various kind of batteries like Lead-Acid, LiFePO4 etc., Flexible and programmable charging module. Ability to select 10 different Amp Hour or Cell Count settings. Equipped with CAN communication interface to realize real-time communication with BMS.
Specification
Spec
Model
|
Output Voltage
-Nominal
|
Output Voltage
-Maximum
|
Output Current
-Maximum
230vac
|
Output Current
-Maximum
115vac
|
TCCH-48-70
|
48V
|
66V
|
70A
|
37A |
TCCH-60-60
|
60V
|
82V
|
60A
|
30A |
TCCH-72-50
|
72V
|
96V
|
50A
|
26A |
TCCH-84-42 |
84V |
112V |
42A |
22A |
TCCH-96-36
|
96V
|
130V
|
36A
|
19A |
TCCH-120-30
|
120V
|
168V
|
30A
|
15A |
TCCH-144-24
|
144V
|
192V
|
24A
|
13A |
TCCH-156-22
|
156V
|
208V
|
22A
|
11A |
TCCH-192-18 |
192V |
258V |
18A |
9A |
TCCH-288-12 |
288V |
389V |
12A |
6A |
TCCH-312-11 |
312V |
417V |
11A |
5.5A |
Note: red = in stock, black = special order.
Technical Target
AC Input Voltage Range
|
AC85V~AC265V
|
AC Input Frequency
|
45~65 Hz
|
AC Power Factor
|
≥0.98
|
Full Load Efficiency
|
≥93
|
Mechanical Shock &
Vibration Resistance Level
|
Conformance to
SAEJ1378 Standard
|
EnvironmentalEnclosure
|
IP65
|
Operating Temperature
|
-40℃ +55℃
|
Storage Temperature
|
-40℃ +100℃
|
Mechanical Dimensions
|
365mm×352mm×139mm
|
Net Weight
|
13.80kg
|
LED Indicator
Red-Green flash
(one second interval)
|
Battery Disconnected
|
Red flash
(three seconds interval)
|
Repair Battery
|
Red flash
(one second interval)
|
<80% Charge Indicator
|
Yellow flash
(one second interval)
|
>80% Charge Indicator
|
Green flash
(one second interval)
|
100% Charge Indicator
|
Protection Features
1. Thermal Self-Protection: When the internal temperature of the charger exceeds 75℃, the charging current will reduce automatically. If exceeds 85℃, the charger will shutdown protectively. When the internal temperature drops, it will resume charging automatically.
2. Short-circuit Protection: When the charger encounters nexpected short circuit across the output, charging will automatically stop. When fault removes, the charger will re-start in 10 seconds.
3. Reverse Connection Protection: When the battery is polarity reversed, the charger will disconnect the internal circuit and the battery, the charging will stop and avoid been damaged.
4. Input Low-voltage Protection: When the input AC Voltage is lower than 85V, the charger will shutdown protectively and automatically resume working after the voltage is normal again.
Making user selection (1-10)
1. There are 10 user selections of Amp Hour (battery size) or Cell Count (number of batteries) available.
2. When the charger is plugged in, the red LED flashes a number of times to indicate the present selection.
3. To change the selection, disconnect AC power, lift the bottom right corner of the Model Number label and hold down the black plastic button while connecting the AC power. Count the number of green flashes and release the button at the desired selection (1-10). The red LED will flash the same number of times to confirm your selection.
Alarms
|
LED Flashing Sequence(One Cycle)
|
Indication
|
1
|
R G _ _ _ _ _ _
|
Wrong Battery
|
2
|
R G R _ _ _ _ _
|
Overcharged
|
3
|
R G R G _ _ _ _
|
Battery Overheated
|
4
|
R G R G R _ _ _
|
Incorrect AC Input Voltage
|
5
|
R G R G R G _ _
|
External Thermal Sensor Fault
|
6
|
R G R G R G R _
|
Communication Interface Fault
|
7
|
G R _ _ _ _ _ _
|
Charger Overheated
|
8
|
G R G _ _ _ _ _
|
Charger Relay Fault;Repair
|
9
|
G R G R _ _ _ _
|
Charger Fault; Repair
|
Note:
1. R—red G—green
2. “_” denotes one second stop
3. Above LED flashing sequence is one cycle, the LED will flash repeatedly when in fault.
Installation & Safety Instructions
1. Preferably the charger should be installed in the horizontal position or installed vertically along radiation tooth. A space of 5cm around the radiation tooth should be open to ensure airflow.
2. Ensure all heat dissipating parts are not obstructed to avoid overheating. Do not put the battery charger near any heat sources. Make sure that free space around the charger is enough to provide adequate ventilation & easy cable socket access.
3. Ensure the consistency between the alternating supply voltage and the allowable voltage input of the charger, please approach a retailer or local Power Utility for enquiry.
4. For safety and electromagnetic compatibility, the battery charger has a 3-prong plug that apply tothe socket with grounded outlet.